Concrete Block and CMU Walls after water, smoke or contamination
CMU is manufactured masonry with porous cementitious webs and often hollow cores. “Cinder block” is a common informal term and does not confirm aggregate composition. Surface water, core water, coatings and attached finishes create different drying problems. Growth can occur on deposited soil; salt deposits can resemble growth. Soot and biological soil can lodge in rough pores.
What the inspection covers
Sound CMU often can be physically cleaned and dried rather than automatically demolished. Establish contamination depth, core access, coating condition and feasible verification.
Cleaning, drying and specialist work
Select controlled cleaning and recovery that do not flood adjacent cavities. Sealing before adequate cleaning/drying can hide residue or restrict vapor movement. Structural cracking, displaced units, heat damage or persistent water entry require qualified structural/masonry assessment; creating core-drain openings needs a considered utility/structural plan.