FRP and PVC Wall Panels after water, smoke or contamination
Fiberglass-reinforced plastic (FRP) panels are resin-and-glass-fiber composite surfaces, often adhesively installed over drywall, plywood or other subwall. PVC wall sheets and high-pressure laminates differ in thickness, expansion, trims and adhesive. A cleanable, water-resistant face does not certify an underlying paper-faced gypsum, MDF or adhesive as dry, nor does a panel itself establish a waterproof joint system. Seam-trim and sealant discontinuity can admit washdown, shower or cleaning water to hidden organic backing.
What the inspection covers
Identify exact brand, panel type and substrate, wetting category/source, trim expansion gaps, silicone/edge joint condition, fasteners and surface bubbles, loose bonds or lifted seams. Compare floor/wall corners and backside where legitimately accessible; meter scans through composite and glue are comparative and not validated wood or drywall MC without manufacturer support. Identify whether the wall is part of a food-contact, healthcare, shower, fire-rated or clean-room assembly before choosing products/repairs.
Cleaning, drying and specialist work
Marlite requires a clean, dry and structurally sound subwall for FRP installation and appropriate sealed trim in high-moisture applications. Retain intact cleanable panel only if substrate and joints can be verified and cleaned/dried; selectively remove panels where water, biological soil, mold-supporting backing, failed adhesion or uninspectable damage beneath prevents sound repair. Your installer handles reconstruction and verifies the required fire and finish ratings; do not spray fog or disinfectant through panels and claim concealed surfaces treated. Document the affected panel size/count, access, underlying material and source repair independently.